Measurement Specialties Inc. NetScanner System (9016, 9021, & 9022) User’s Manual
3 - 44
bbbb (hex)
data selected for inclusion in each stream packet
0001 **
Enable Valve Position Status (reserved for future use)
0002
Enable DH Temperature Status (see bit map below)
0010
Enable Pressure EU Data (default if05” never executed
after00”)
0020
Enable Pressure A/D Counts
0040
Enable Pressure Voltages
0080
Enable DH Temperature EU Data (degrees C)
0100
Enable DH Temperature A/D Counts
0200
Enable DH Temperature Voltages
Any DH Temperature Status datum is delivered as a two-byte binary bit map
(16-bit, big endian) with each bit representing the status of DH #16 through DH #1
respectively. A bit value of 0 (zero) indicates the DH is operating within its
specified limits. A value of 1 (one) indicates the DH is outside its specified
limits.
Bit #
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Chan #
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Binary
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
Hex
8
0
0
1
The above example indicates that Channels 1 and 16 are operating outside the
specified temperature limits.
NOTE: Selecting too many other data groups will compromise module
performance.